GetDPLocations failed with error 0x80072ee2

Recently I was helping an old colleague setting up an SCCM Current Branch 1606 site. When installing the SCCM client via client push, the ccmsetup.log on the client failed with the errors “GetDPLocations failed with error 0x80072ee2” and “Failed to get DP locations as the expected version from MP ‘site.domain.com’. Error 0x80072ee2”

The error 0x80072ee2 translates to “The operation timed out Source: Winhttp”. I checked from the client that I could successfully ping the site server which I could not, which is why it was failing. Doing an nslookup revealed that the site server was resolving to an incorrect IP. The site had some DNS issues. Once updating the DNS the clients could connect to the MP then download the ccmsetup files and install fine.